L_TT1P_ElectricalShaftVel: No error message in the case of linear axes and dwCouplingMode = 1 (corrected from V3.14)

Corrected from:
L_TT1P_TechnologyModules_LM (V3.14.0.21)
 
Response of the new version:
If linear axis measuring systems are used and dwCouplingMode = 1 (coupling via cycle lengths of the axes) is used as coupling mode, a corresponding warning will be output. (InvalidCouplingMode).
As soon as a request to close the clutch (xSyncVel = TRUE) is set after this, the technology module changes with the same error text to the "Error" state.
 
 
What happens?
The axes are coupled. The coupling factor is not directly visible.
 
When does this behaviour occur?
The behaviour occurs if linear axes are used with the following parameter setting: dwCouplingMode = 1 (coupling via cycle lengths of the axes)
 
Which products are affected?
L_TT1P_ElectricalShaftVel function block from the L_TT1P_TechnologyModules_LM library (V3.12.0.9 and higher)
 
Short-term measures:
Always select dwCouplingMode = 0 as coupling mode for linear axes.
 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201500900/1/