i950 TA Automotive, L_TF2P_TablePositioningBase: Absolute positioning without reference leads to a warning
Removed from:
Behavior of the new version:
Description of the behavior:
A warning is displayed instead of an error. The technology function remains in the "Standby" state instead of switching to the "Error" state.
Conditions under which the behavior occurs:
If no reference is available, an attempt is made to create an absolute start positioning.(xExecutePositioning at L_TF2P_TablepositioningBase, 0x5030:010 Bit 20 Start positioning)
Affected products:
Servo Inverter i950 with TA Automotive (from V1.10.0.3102)
Technology module L_TF2P_TablePositioningBase from library L_TF2P_TechModulesFollowingPositioning (from V3.30.00.62)
Short-term measures, Recommendations, Rating:
Changing the behavior would lead to incompatibility. Therefore, the behavior is not adjusted.