Corrected from:
Library L_TB2P_TechModulesBasic (from V03.26.00)
(Update via Easy Package Manager)
Response of the new version:
The following outputs of the function module L_TB2P_AxisInterface give their value in the resolution of the parameters from which they are read.
- lrActualMotorCurrent --> Actual motor current in % with 1 decimal place
- lrThermalLoadDevice --> Ixt load without decimal place
- lrThermalLoadMotor--> I²xt load without decimal place
What happens?
The following outputs of the function block L_TB2P_AxisInterface are scaled too small by factor 1000.
- lrActualMotorCurrent --> Actual motor current in % scaled too small by factor 1000. 4 decimal places
- lrThermalLoadDevice --> Ixt load with 3 decimal places.
- lrThermalLoadMotor--> I²xt load with 3 decimal places
When does the behaviour occur?
When these outputs of FB L_TB2P_AxisInterface are used.
Which products are affected?
Function module L_TB2P_AxisInterface from library L_TB2P_TechModulesBasic
Short-term measures:
None
Evaluation / recommendations:
Automatic Translation