Load Machine Module: Existing machine module cannot be overwritten (corrected from V3.22)

Corrected from:
Application Template V3.22

Response of the new version:
The context menu command 'Load Machine Module' can be used to update or partially update a machine module used in the project.

What happens?
A User-MM that is already used in the PLC project is to be updated. In the 'Load Machine Module' dialogue, in which it is possible to select which objects of the User-MM are to be updated, the <OK> button remains deactivated.

When does the behaviour occur?
The behaviour described above occurs when the name of the machine module is already used in the project.

Which products are affected?
Application Template V3.21

Short-term measures:
Rename machine modules before loading the MM with the same name.

Evaluation / recommendations:
Due to this functional restriction, machine modules used in the project cannot be updated via the context menu command 'Load Machine Module'.

Automatic Translation

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202000231/1/
Modulo di contatto