Mains switching has to be performed after loading default setting in order for touch probe, homing switch (DI2) to be detected (eliminated as of OPERATING SYSTEM V8.3)
Eliminated as of:
ECS Application OPERATING SYSTEM as of V8.3
Behaviour of the new version?
The touch probe edge at the homing switch (DI2) is now detected correctly after loading the default setting; intermediate mains switching is not required.
Which products are affected?
ECS Application OPERATING SYSTEM <= V8.0
What happens?
Drive does not respond to the signal at the touch probe input.
When does the problem occur?
After loading the default setting, if intermediate mains switching is not performed.
The problem affects the Posi&Shaft application software in particular and occurs frequently during homing.
Diagnostics options?
Generate edge at touch probe input DI2: Drive does not respond as expected.
Short-term measures/recommendations?
Perform mains switching once after loading the default setting. After this, touch probe evaluation functions without errors.
Evaluation:
No particular relevance for practical applications, as mains switching is carried out as standard during commissioning.
Taxonomy:
ECSxA application
,
ECSxE power supply module
,
ECSxK capacitor module
,
ECSxM motion
,
ECSxP position and shaft
,
ECSxS speed and torque
,
ECS servo inverters
AKB-ID:
201010968
Last update:
2023/09/09
Category:
Informations sur la version
Lenze reserves the right to change information on this page at any time. Any liability for the accuracy of the information is excluded.