URL:
/en-es/go/akb/200401127/1
Output terminals change their status when transferring parameters
Which products are affected?
All EVS9300 and EVF9300 drive controllers…
URL:
/en-es/go/akb/202300007/1
Menu items of the Application Template are not displayed in the PLC Designer (corrected from V3.27)
Corrected from:PLC Designer…
URL:
/en-es/go/akb/200401094/1
Faulty analog output signal of function block INT2
Which products are affected?
9300 vector 0.37…90 kW SW V2.1
What happens?
The…
URL:
/en-es/go/akb/200401093/1
Limit speeds C0038/x and JOG speeds C0039/x have rounding off errors
Which products are affected?
9300 vector 0.37…90 kW SW V2.1
What…
URL:
/en-es/go/akb/200401092/1
OU monitoring - the drive controller indicates error code 2020 (warning) instead of error code 1020 (message)
Which products are affected?…
URL:
/en-es/go/akb/202300073/1
Design Time - User Groups: Advanced settings are editable although they are displayed as disabled
Corrected from:EASY UI Designer…
URL:
/en-es/go/akb/202300035/1
MC_MovePath, setpoint filter and NC program: Axis group stops in GroupMoving state under certain conditions (corrected from…
URL:
/en-es/go/akb/200401090/1
Automatic DCB with vector control
Which products are affected?
9300 vector 0.37…90 kW SW V2.1
What happens?
The motor current…
URL:
/en-es/go/akb/202300039/1
L_MC1P and FB 'L_IE1P_SetErrorSingle': If the error reaction is set to immediate locking of the controller (Cinh), the brake is…
URL:
/en-es/go/akb/202300033/1
L_MC4P_DifferentialDrive2x2 and L_MC4P_DifferentialDrive3x3: Coupling of a linear with a rotary axis fails (corrected from…
URL:
/en-es/go/akb/200401051/1
QSP shortly after the requested change of direction of rotation leads to sudden changes in torque
Which products are affected?
9300…
URL:
/en-es/go/akb/200401030/1
Incorrect motor data when selecting motors via C0086
Which products are affected?
9300 vector 0.37…90 kW SW V2.1
What happens?
After…
URL:
/en-es/go/akb/200401024/1
Codes C0002 to C0009 cannot be selected via function block FEVAN1
Which products are affected?
9300 vector 0.37…90 kW SW V2.1
What…
URL:
/en-es/go/akb/200401023/1
The 20 kbaud CAN transmission rate is not supported
Which products are affected?
9300 vector 0.37…90 kW SW V2.1
What happens?
The…