L_TB2P: TM-BasicMotion and SS2-Limiter: Renewed homing not possible after limiter stop (eliminated from V3.20.0)

Corrected from:
Library:  L_TB2P_TechModulesBasic  (FAST TM)  as of V03.20.00.27 
                      (Update via Package-Manager)
Response of the new version:
A reference run can be restarted after an SS1 and SS2.
 
What happens?
If a reference run with an SS1 or SS2 is interrupted, it cannot be restarted without an xResetError being carried out on the TM.
 
When does the behaviour occur?
An SS1 or SS2 is executed during homing.
 
Which products are affected?
Library:  L_TB2P_TechModulesBasic  (FAST TM)

Short-term measures:
After an SS1 and SS2 during a reference run, perform an xResetError on the TM.
 