Which products are affected?
8400 StateLine / HighLine with firmware version 01.00 or higher with fieldbus modules
What happens?
If the fieldbus module is supplied with voltage before the standard device is connected, the CE04: MCI communication error error message may be issued.
Although there is no reason for this error message, a Logbook entry is made. This is complicating the evaluation of the Logbook.
When does the problem occur?
If the CE04 error configuration is activated (C1501/1..2 = 1...6), an entry may be made to the Logbook / an error message may be issued at switch-on.
Possible diagnostics?
A Logbook entry is made although the error did not occur.
Short-term measures / recommendations?
None
Evaluation:
Only occurs sporadically under the described conditions.
Taxonomy:
8400 HighLine frequency inverters
,
8400 StateLine frequency inverters
,
Axis bus
,
IO-Link
,
AS-I E84DGFCA
,
AS-I FIF E82ZAFFC
,
Fieldbus modules
AKB-ID:
201006037
Last update:
2023/09/09
Category: