Wird die Achse mit MoveAbs/MoveRel aus der Visualisierung heraus angesteuert (CtrlBasicMotion), wird der über die Visualisierung eingetragene Wert in SetPos_Dist verwendet.
What happens?
The value entered via the PLC-Designer visualization in SetPos_Dist is not used
When does the behaviour occur?
The axis is to be controlled with MoveAbs/MoveRel from the visualization (CtrlBasicMotion).
Which products are affected?
Function modules L_TF2P_SpeedControlBase, L_TF2P_TablePositioningBase and L_TF2P_VirtualMasterBase from library L_TF2P_TechModulesFollowingPositioning Function modules L_TW2P_WinderDancerCtrlState and L_TW2P_WinderTensionCtrlState from library L_TW2P_TechModulesWindingTraversing
Short-term measures:
Wiring of input scCtrlBasicMotion.lrPos_Dist from within the application.
Taxonomy:
L_TF2P_TechModulesFollowingPositioning
,
L_TW2P_TechModulesWindingTraversing
AKB-ID:
202000385
Last update:
2026/05/08
Category:
Informations sur la version