Incrementing of the CAN telegram counter under code C0360/005
Which products are affected?
9300vector 0.37…90 kW SW7.3 and 9300vector 110…400kW SW7.1
Function description:
In contrast to the 'cyclic transmission' setting the telegram counter C0360/005 in the CAN-OUT3 function block does not count up in case of the 'event-controlled transmission' because an incrementing of the telegram counter has not been planned for this type of transmission.
The function has now been extended in such a way that an incrementing of the telegram counter is also possible in case of an 'event-control transmission' process.
Application:
Use of the telegram counter in the CAN-OUT3 function block.
Taxonomy:
9300 vector EVF93xx-EH hoist frequency inverters
,
9300 vector EVF93xx-EV frequency inverters
,
9300 vector frequency inverters
AKB-ID:
200603286