EtherCAT master: 'SlaveAutoRestart' parameter has no effect

     

Corrected from: 

-

 

Behavior of the new version: 

-

 

Description of the behavior:

Manually setting the 'SlaveAutoRestart' parameter, which is located in the 'EtherCAT Parameter' tab of the EtherCAT master, has no effect.

 

Conditions under which the behavior occurs: 

The parameters listed in the 'EtherCAT Parameters' tab are internal system parameters. Parameters that are not visible in another tab card or dialog have no function or are not used by the system.

 

Affected products:

Controller c430 from V1.11

Controller c520 from V1.0
Controller c550 from V1.0

Servo inverter i950 from V1.0

Short-term measure, recommendations, evaluation: 

Use the setting options on the tab cards of the EtherCAT master instead of adjusting the parameters in the 'EtherCAT parameters' tab card.