L_MC1P_BasicActuatingSpeed and virtual mode for inverter i550: EXCEPTION [AccessViolation] occurs when starting the PLC program (fixed from V03.30.00)

Removed from:
Library:  L_MC1P_MotionControlBasic  (FAST Motion)  as of V03.30.00
                      (Update über Package-Manager)
 
Behavior of the new version:
The function block L_MC1P_BasicActuatingSpeed can now also be used with an i500 axis in virtual mode.

 
Description of behavior:
L_MC1P_BasicActuatingSpeed:
When using an i500 axis in virtual mode, the error message (EXCEPTION) [AccessViolation] occurs after starting the PLC program. 

Under what conditions does the behavior occur?
  • L_MC1P_BasicActuatingSpeed wis called iin the application and
  • at the Axis input, an i500 axis is connected and
  • in the i500 axis, virtual mode is active
Affected products:
Library:  L_MC1P_MotionControlBasic  (FAST Motion)
 
Short-term measures, Rating/Recommendations:


[Automatic Translation]
URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202400109/1/