L_TS2P_CrossCutter: Status xTrimActive invalid (fixed from V3.30.0)

Fixed as of:
L_TS2P_TechModulesSynchronizingCamming (as of V3.30.0).
(Update via Easy Package Manager)

Behavior of the new version:
When the trim function is used, the status is always dset xTrimActive  = TRUE displayed,


Description of behavior:
The status xTrimActive is invalid

Conditions under which the behaviour occurs:
It is trimmed via xTrimPos, xTrimPos of the cross-cutter in the synchronized area.

Affected products:
Library L_TS2P_TechModulesSynchronizingCamming 

Short-term measures, Recommendations, Rating:
Der Status xTrimActive ist inaktiv. The evaluation of whether the trim function is active must be derived via the xTrimPos and xTrimNeg inputs. 


[Automatic Translation]
URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202300343/1/
Contact form