L_TS2P_CrossCutter: CrossCutter does not restart after an SS1 (fixed from V3.30.0)

Lifted from:
Library L_TS2P_TechModulesSynchronizingCamming (as of V3.30.0)
(Update via Easy Package Manager)

Behavior of the new version:

In the situation described below, the parking position is approached when xExecuteMoveToParkPos = True. 


Description of the behavior:

After SS1, the function for moving to the parking position (xExecuteMoveToParkPos) cannot be executed. 
Under what conditions does the behavior occur?
  • The TM L_TS2P_CrossCutterState is moved to the park position (xExecuteMoveToParkPos = TRUE)
  • The SS1 function is activated and cancels the drive to the park position
  • The SS1 function is deactivated when stationary
  • The journey to the parking position is ordered again 
Affected products:
Function block L_TS2P_CrossCutterState from library L_TS2P_TechModulesSynchronizingCamming

Short-term measures:
After deactivating the SS1 function the xAbort = TRUE and xAbort = FALSE function can be activated again. The approach to the parking position can then be restarted 

Rating/Recommendations:
The approach to the parking position can also be carried out after SS1, taking into account the short-term measure. Alternatively, the function for absolute positioning can always be used 