Increasing the transmission factor between the encoders in the two-encoder concept

Function extension:
The value range is limited in FW version V1.0 in the way that a maximum transmission ratio of i=500 can be realized.
As of firmware version V1.1, the maximum transmission ratio is i= 655.35.

Code number 15501 Position encoder gear factor Factory setting is 100%.

Setting of the gear factor between motor and position encoder,
e.g. 100 % => i = 1.00
2543 % => i = 25.43
65535 % => i = 655.35

Contained in which products?
Safety module SM302 FW Version 1.10

Usage:
Safety functions with two-encoder concept and higher gear ratio


URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202300046/1/
Contact form