EASY Starter: Switching the technology application (TA)

Question:
Can the technology application in a Servo Inverter i950 be switched by downloading parameters from a file?
 
Answer:
No. If the 'Parameters' option is selected in the EASY Starter 'Download' dialogue, then the selected parameter set file (*.GDC or *.LDA) can only be loaded into the i950 servo inverter if the same technology application (TA) is set in the parameter set file and in the i950. Otherwise the EASY Starter displays an error message.

If the option 'Device application (without safety parameter set)' is selected in the EASY Starter 'Download' dialogue, then the i950 switches to the TA set in the device application file when the device application file (*.LDA) is downloaded.

The EASY Application Loader shows the same behaviour.