Error message when updating the project (fixed from V2.33)
Corrected from:
Engineer V2.33
Response of the new version:
The error message 'Error during PLC Designer component registration' no longer occurs after installing Engineer V2.33, not even with older Engineer versions installed in parallel on the PC.
What happens?
When updating an Engineer project, the error message appears in the message window:
Error during PLC Designer component registration. Please restart the Engineer and ensure successful completion of the compilation process.
When does the behaviour occur?
The error message described above occurs in very rare cases when updating projects from the Servo Inverter 9400 HighLine. Engineer versions <V2.33 may show this error message when installed under Windows 10.
Which products are affected?
L-force Engineer from V2.0
Short-term measures:
Contact Lenze Service.
Evaluation/Recommendations:
To update projects for the 9400 HighLine Servo Inverter, the L-force Engineer uses the compiler of the PLC Designer V0.4. The error message appears if the PLC Designer is not correctly registered in Windows.