L_TT1P_ElectricalShaftPos: The measuring point MP04_lrSetClutchPos shows invalid values in state eTMState = READY (corrected from V3.23.0)

Corrected from:
Library: L_TT1P_TechnologyModules_LM (from V3.23.0.14) 
Update via Easy Package Manager.

Behaviour of new version:
The measuring point MP04_lrSetClutchPos displays valid values as soon as the conductance axis is connected and the TM is activated via xEnable = TRUE. 

BWhat happens?
The measuring point MP04_lrSetClutchPos shows invalid values and position jumps.

When does the behaviour occur?
The measure point always returns invalid values if the state of the TM eTMState = READY is switched.

Which products are affected?
Function module L_TT1P_ElectricalShaftPosHigh from library L_TT1P_TechnologyModules_LM.

Short-term measures
The measuring point MP04_lrSetClutchPos should not be used in the state eTMState = READY.

Evaluation/Recommendations:
The function of the clutch is independent by the measuring point MP04_lrSetClutchPos. The display of the measuring point provides valid values as soon as the clutch is closed xSyncPos = TRUE.