L_TT1P_StackerCrane: Error 19810 with xHalt = TRUE and active Osc. Comp. 8corrected from V3.23.0)

Corrected from:
Library: L_TT1P_TechnologyModules_LM (from V3.23.0)
Update via Easy Package Manager.

Behaviour of new version:
The function xHalt can be assigned together with the active function of the vibration compensation (xOscComp = TRUE).  

What happens?
The TM L_TT1P_StackerCraneAxisControl reports the error eErrorID = 19810 (ChangeOfOscCompModeLocked).

When does the behaviour occur?
If the xHalt function is activated during a movement and the vibration compensation function is switched to active (xOscComp = TRUE)

Which products are affected?
Function block L_TT1P_StackerCraneAxisControlbase from library L_TT1P_TechnologyModules_LM (from V3.20.0)

Short-term measures:
During execution of the xHalt function, the AP3 and AP4 points of attack should be activated:
- AP03_xOscCompPosScaled = TRUE with AP03_lrOscCompPosScaled := scSignalFlow.MP02_lrOscCompPosScaled
- AP04_xOscCompLoadScaled = TRUE with AP04_lrOscCompLoadScaled := scSignalFlow.MP01_lrOscCompLoadScaled

 In the READY state the attack points can be deactivated again:
- AP03_xOscCompPosScaled = FALSE
- AP04_xOscCompLoadScaled = FALSE

Evaluation/Recommendations:
Taking into account the short-term measure, the error state is no longer switched under the given condition. Thus, the function "stop" in combination with the function of vibration compensation is given.