L_TT1P_ElectricalShaftPosHigh: Master Offset is not extended with Limited (corrected from V3.22.0)

Corrected from:
Library:  L_TT1P_TechnologyModules_LM  ab V3.22.0.19
                      (Update über EASY Package-Manager)

Response of the new version:
The technology module can now also move the master offset with the use of the limited axes.
 
What happens?
The L_TT1P_ElectricalShaftPosHigh technology module does not move the master offset, which is assigned via the "lrSetOffsetMaster" input.
 
When does the behaviour occur?
The master and slave axes are used in limited dimension system "Limited".
 
Which products are affected?
Function block L_TT1P_ElectricalShaftPosHigh from library L_TT1P_TechnologyModules_LM V3.19.0
 
Short-term measures:
As an alternative to the master offset, the slave offset can be set via the "lrSetOffsetSlave" input.
 
Evaluation/Recommendations:
Taking into account the short-term measure, an offset can be set in the synchronous run between master and slave axes. For this purpose, the profile for moving the slave offset must be specified in the units of the slave axis.
 