L_TT1P: Error message when the library is inserted into POUs (eliminated from V3.20.0)

Corrected from:
Library: L_TT1P_TechnologyModules_LM (FAST Motion) from V03.20.00.78
                       (Update via Package Manager)
 
Response of the new version:
The libraries can now be inserted into POUs without error messages.
 
What happens?
This error message appears when opening a PLC project:
Library Manager: Could not open library '#L_MC1P_MotionControlBasic'. (Reason: The library 'L_MC1P_MotionControlBasic, 3.19.0.999 (Lenze)' has not been installed to the system.)
 
When does the behaviour occur?
The library L_TT1P_TechnologyModules_LM V3.19.0.25 was not inserted at the device, but in the window "POUs".
 
Which products are affected?
Library L_TT1P_TechnologyModules_LM V3.19.0.25
Library L_MC1P_MotionControlBasic V3.19.0.101
Library L_UMTP_Mathematics V03.19.00.68
Short-term measures:
The L_MC1P_MotionControlBasic library can be set to V3.19.0.101 using placeholders.
Afterwards the error message does not appear anymore when the project is opened.
 
Evaluation/Recommendations:
Taking into account the short-term measures, the project can be translated. This does not restrict the functionality of library L_TT1P_TechnologyModules_LM.