L_TT1P_RegisterControl, L_TT1P_CrossCutter: Dead time for touchprobe correction is determined incorrectly (fixed from V3.19.0)

Fixed:
Library: L_TT1P_TechnologyModules_LM as of V03.19.00.25
                    (Update over the Easy Package Manager)
Behaviour of the new version:
The axes have no offset after compensation.
Description of the behaviour:
The axes have an offset after adjustment. The offset is 2 cycles.
 
Under what conditions does the behaviour occur? 
Technology modules L_TT1P_RegisterControlBase, L_TT1P_RegisterControlState or L_TT1P_CrosscutterState are used.
 
Affected products:
Technology modules L_TT1P_RegisterControlBase, L_TT1P_RegisterControlState and L_TT1P_CrosscutterState from library L_TT1P_TechnologyModules_LM
 
Short-term measures:
Application correction of dead times with the help of attack points
    scAccessPoints.AP03_xTpAxisDelayCycle  
    scAccessPoints.AP03_lrTpAxisDelayCycle
    scAccessPoints.AP04_xTpAxisCompFactor
    scAccessPoints.AP04_lrTpAxisCompFactor