L_MC2P_TappetRegister: With tappet type "PositiveTime" FastOutput switches only once (corrected from V03.19.00)

Corrected from:
Library:   L_MC2P_MotionControlCam  (FAST Motion)  from V03.19.00.15 
                      (Update via Package-Manager)
 
Response of the new version:
Time tappets can now be used for both directions without restrictions again.
 
What happens?
The FB 'L_MC2P_TappetRegister' does not function correctly with tappet type "PositiveTime".
 
When does the behaviour occur?
The error occurs when time tappets are used that are additionally charged with negative speed.
The tappets are still switched correctly in the first cycle, but the tappets cannot be switched on for the following cycles

Which products are affected:
Library:  L_MC2P_MotionControlCam  (FAST Motion)
 
Short-term measures, Evaluation/Recommendations:
The time tappets can be changed to position tappets, instead of a time, the switch-off position must then be specified.
 