L_TT1P_CrossCutter: Mark window in "TP_From_Slave" mode cannot be used (corrected from V3.18.0)

Corrected from:
Library: L_TT1P_TechnologyModules_LM V03.18.0.33
                    (update via Easy Package Manager)
 
Response of the new version:
When using the scPar.eTpMode = TpFromSlave mode, mark correction now also works when the mark window is activated.
 
What happens?
Sporadically, cuts are not made on the cutting mark (touch probe).
 
When does this behaviour occur?
The behaviour occurs when using the scPar.eTpMode = TpFromSlave and a mark window is used (scPar.lrMarkWindowSize <> 0).
 
Which products are affected?
L_TT1P_CrossCutter technology module from L_TT1P_TechnologyModules_LM library (V3.17.0.47 and higher)
 
Short-term measures:
At present, the TpFromSlave mode can only be used without mark window.  
 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201800231/1/
Contact form