L_TT1P_ElectricalShaftVelocity: Drift with i700 and inhibited master (no changes planned)

Corrected from:
Library: L_TT1P_TechnologyModules_LM  from:   (no changes planned)

Response of the new version:
No software modifications planned.


What happens?
FB L_TT1P_ElectricalShaftVel: The slave axis is drifting although the master axis is at standstill.
 
When does this behaviour occur?
FB L_TT1P_ElectricalShaftVel: A velocity clutch is used with the ElectricalShaftVel technology module and the i700.
The master axis is inhibited while the clutch of the ElectricalShaftVel TM is active.
The behaviour does not occur with an 9400.
  
Which products are affected?
Library: L_TT1P_TechnologyModules_LM  from V03.12.00.9
 
Short-term measures:
If the master axis is inhibited while the velocity clutch is active,
the slave axis should be inhibited as well. This prevents the slave axis from drifting.


URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201700393/1/