L_TT1P_TablePositioning: Axis continuously traverses in one direction (eliminated from V3.12)

Eliminated from:
L_TT1P_TechnologyModules_LM V3.12.0.9
 
Behavior of new version:
The positioning is done with the profile parameters of the first profile. An endless movement in one direction does no longer occur.
 
 
What happens?
The positioning axis continuously traverses with the speed of the first profile in one direction
 
When does this behaviour occur?
The behaviour occurs if a profile linkage with final speed in the first profile and a relative sequence profile is cancelled with xHalt while executing the relative profile and
the positioning process is restarted with xExecutePositioning after this.
 
Which products are affected?
L_TT1P_TablePositioning function block from the L_TT1P_TechnologyModules_LM library (V3.10.0.8 and higher)
 
Short-term measures:
Do not use the above-mentioned profile configuration until the function restriction has been removed.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201500810/1/
Contact form