Ethernet status Client x in code C01511 - meaning

Question:
What is the meaning of Ethernet status Client x in code C01511 subcodes 1...3?

Answer:
When Ethernet port 9410 is used to establish an Ethernet connection with the Ethernet communication module of 9400 Servo Drives, the IP address of the server (Engineering PC with L-force Engineer, customer PLC, etc.) is entered in code C01510. You can establish 3 Ethernet connections in parallel with the module. The corresponding IP addresses of the counterpart are indicated in subcodes 1-3 of code L-C01510.

Code C01511, Ethernet status of client x, subcodes 1-3, shows the current status of the three possible connections. The value '1' means that a connection has been established. If the connection is interrupted or if the Engineering PC, the PLC, etc. has not communicated with the Ethernet module for three minutes, the status in code C01511 changes to 'Not connected' (value = '0'), and the Ethernet port is released again.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201014225/1/