Functional description
Firmware version V7.1 provides monitoring for voltage failure during the parameter saving process via device command C0002 = 11 ('Save start parameters'). If the parameter saving process cannot be completed correctly due to a voltage failure, the controller will report an error, 'Power down during par save', after mains recovery. The error can be acknowledged if device command C0002 = 11 is executed once again and the parameter saving process is completed successfully.
So far there had been no indication of an interrupted parameter saving process after mains recovery.
Applications
Applications which involve a change of current parameter values during operation and a power-failure-proof way of saving of these changes.
Included in which products/versions?
All 9400 HighLine axis controllers with firmware version 07.01.60.00 or higher
search terms: non-volatile parameter store, fault number 613416972, error + module ID 9437196