ECSx: Operation with EMF 2133 Profibus communication module

Question:

Which configuration of the EMF 2133 Profibus communication module can be used from the belonging GSD file for triggering an ECSx controller?

Answer:

For the project planning of the PROFIBUS-DP the controller master data file (LENZ2133.GSD) of the EMF 2133 communication module is supposed to be read in the Profibus master. In order to be able to make use of the status and control signals in correspondence to the definition in the ECS operating instruction, chapter 'Configuration of control interface' a process data configuration with:

Lenze device control with and without DRIVECOM-parameter data channel

has to be selected. E. g. all constellations of the GSD file which are marked with 'AR' (device control) behind the number of process data.

Note:
The process data configurations DRIVECOM - control and PROFIDRIVE - control are not permissible!!

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200602681/1/