External DC 24 V supply of the SSI interface module

Question:
Must the external voltage supply DC 24 V at the SSI interface module always be connected to the terminal 1 (DC +24 V) and terminal 10 (GND)?

Answer:
Yes, the external voltage supply DC 24 V must always be connected to the terminals 1 and 10, as it is also required for the internal supply of the module.
External supply voltage DC 24 V:
  • Supply of module components
  • Supply for outputs
  • Supply of the SSI encoder

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200506440/1/
Contact form