Switch-off temperature of the heatsink (OH threshold) (V2.3 onwards)

Which products are affected?
Supply module ECSxE series, operating software V2.3

Function description
The switch-off threshold for the heatsink temperature (OH threshold) has been increased from approx. 80 °C to 90 °C and thus been adapted to the axis controllers.
Please observe the following instructions when downloading the new operating software V2.3 subsequently:

The new OH threshold is not accepted automatically in order to avoid that the device-specific adjustments stored in the device get lost. Therefore, the OH threshold has to be adapted manually after an update to V2.3. Regarding this the following codes are to be written by observing this order:
  • C0304 = 318
  • C0305 = 326
  • C0308 = 40
  • C0309 = 900 (corresponds to 90.0 °C)
  • C0308 = 0
  • C0309 = 1040 (store device set)

Control measure:
  • Switch the 24 V supply off and on again
  • Enter C0308 = 40
  • Display of C0309: 900 (corresponds to 90.0 °C)

Applications
Only relevant in case of applications with a very high utilisation of the supply module.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200407062/1/