OU monitoring - the drive controller indicates error code 2020 (warning) instead of error code 1020 (message)

Which products are affected?

9300 vector 0.37…90 kW SW V2.1

What happens?

When exceeding the overvoltage threshold, the drive controller inhibits the inverter through IMP inhibit for self-protection purposes. Error code 2020 (OU warning) is wrongly indicated under C0168/x. This does not match with the documentation. Error number 1020 (OU message) should have been indicated instead.

When does the problem occur?

The DC-bus voltage exceeds the overvoltage threshold (OU) due to operation in generator mode. The error number cannot be interpreted correctly when being enquired via a communication module since it is not included in the documentation.

Possible diagnostics?

See response under 'What happens?'

Short-term measures/recommendations?

If the error number is evaluated or displayed, the code 2020 is to be equated with the OU message.

Evaluation:

Display error which does not affect the drive performance.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200401092/1/
Contact form