DFSET, DFRFG, TP synchronisation and TP-Start fail to operate

Which products are affected?

9300EP servo positioning controller versions V2.5, V2.6 and V6.1 only.

What happens?

The function TP synchronisation of master frequency processing DFSET and the function TP-Start in the DFRFG failed to operate. There was no response to the TP signals.

When does the problem occur?

When using the following functions:
  • TP synchronisation of master frequency processing DFSET
  • TP-Start in the DFRFG

Possible diagnostics?

The TP signals show no effect and even the corresponding status outputs are not set accordingly.

Short-term measures/recommendations?

None.

Evaluation:

Functional limitation is already detected during initial commissioning.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/20035141/1/
Contact form