Current home position, update

Which products are affected?

9300EP servo positioning controller version V2.1

What happens?

The indication of the 'current home position' under C1220/8 and C1221/8 is not updated after homing and 'set home position' function.

Eliminated function restriction

The indication of 'current home position' under C1220/8 and C1221/8 was not updated after homing and the 'set home position' function, in absolute positioning without absolute value encoder.

Possible diagnostics?

Set home position and observe the above display codes.

Short-term measure/recommendations?

None, but there is no effect on operation of the positioning controller.

Evaluation:

Uncritical because only display values are affected.