Continuous path control, POS-PSET-EXT, changeover

Which products are affected?

9300EP servo positioning controller versions V2.1

What happens?

The drive jerks during changeover process.

Eliminated function restriction

Cyclic input of position setpoints, e.g. from an external continuous path control via the input POS-PSET-EXT: When changing over from the internal profile generator to the external position setpoints the drive may have jerked.

Possible diagnostics?

Changover between external and internal profile generation.

Short-term measures/recommendations?

By means of function block connection do not pass the speed precontrol on to MCTRL for 4 ms:
  • POS-NOUT via ASW to MCTRL-N-SET.
  • Switch ASW by means of DIGDEL, delayed by 4ms, to the input POS-PSET-SWT = High.

Evaluation:

The jerk was only caused by the speed precontrol signal so the jerk did not have any influence on position.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/20035116/1/