S-ramp and manual positioning at position limits

Which products are affected?

9300EP servo positioning controller version V2.1

What happens?

When reaching the position limits the drive drifts beyond these limits.

When does the problem occur?

With S-ramp activated the drive in manual mode drifted beyond the position limits when they were reached, as long as 'manual positioning' had still being actuated.

Possible diagnostics?

With S-ramp activated in manual mode move to the position limits. If the manual positioning signal continues to prevail, the drive continues to drift.

Short-term measures/recommendations?

Do not actuate manual positioning any longer if position limits have been reached.

Evaluation:

Uncritical because with manual positioning the drive is 'monitored' by the operator.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/20035113/1/
Contact form