Communication abort in case of the 8200 vector after modification of the address

Which products are affected?
Global Drive Loader version 1.0, 1.2
8200 vector as of V2.1

What happens?
When transferring a parameter set file in a 8200 vector device the communication with the drive controller is interrupted. Error message A102h is indicated.

When does the problem occur?
If the system bus address (C0350) is changed by using the parameter set file the parameter set transfer will be aborted at the last code by indicating an error.

Possible diagnostics
None.

Short-term measures/recommendations?
This function restriction has been eliminated with version 2.0 of the Global Drive Loader.

Evaluation:
Despite the abort of the parameter transfer and the indication of the corresponding error message all code values have been transferred.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/20032701/1/