Current controller setting does not depend on motor selection

Which products are affected?
  • EVS93xx-EI (Servo PLC version 2.1)
  • EVS93xx-ET (Servo PLC version 2.1)

What happens?

The drive does not perform dynamically or overcurrents occur.

When does the problem occur?

When selecting a motor via code C0086 code C0075 (Vp current controller) and C0076 (Tn current controller) are not adapted correspondingly.

Possible diagnostics?

When changing code C0086 codes C0075 and C0076 can be checked and their values can be corrected accordingly.

Short-term measures/recommendations?

If the Global Drive Control software is used to change offline code C0086 for motor selection codes C0075 and C0076 of the current controller will be adapted correctly. The parameter set which has been created offline can be loaded in the Servo PLC.