PROFINET: Sporadically no transfer of the station name to 0x2382/4 after establishing communication

Lifted from:

Behavior of the new version:



description of the behavior:

When setting the PROFINET station name via DCP, the set station name is sporadically not transferred to the controller objects. 

Object 0x2381/4 and 0x2382/4 remain empty, which leads to an incorrect configuration when the fieldbus is restarted via object 0x2380 and the device can no longer be connected via the IO controller.


Conditions under which the behavior occurs:

  • This sporadic error may occur during commissioning / configuration of the device.

 
Affected products:
Controller C430


Short-term measures, Recommendations, Rating:
  • Make sure that the correct values for 0x2381/4 are adopted when saving the parameter set.

  • Set the station name via DCP again or restart the device, which restores the last saved parameters.


[Automatic Translation]
URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/202300422/1/