Tripping of SSI encoder error message: "LS_MultiEncoder: Max. position jump"

Corrected from: 

  • Inverter Drives 8400 protec HighLine V08.01.00 0.37 kW - 5.5 kW
  • Inverter Drives 8400 protec HighLine V16.01.00 7.5 kW


Response of the new version:

From the new version onwards, an SSI-encoder overflow will be included in the "LS_MultiEncoder: Max. position jump" monitoring function and no error will be tripped.


 

What happens?

When the max. position jump monitoring function is active, the "LS_MultiEncoder: bFail" output bit is not set correctly.

 

When does this behaviour occur?

The behaviour occurs when using a rotary SSI encoder and overtravelling the value range (overflow of the position read by the SSI encoder). Activation of code C1112:4.

 

Which products are affected?

  • Inverter Drives 8400 protec HighLine lower than V08.01.00 0.37 kW - 5.5 kW
  • Inverter Drives 8400 protec HighLine lower than V16.01.00 7.5 kW

Short-term measures:

-

Evaluation/recommendations:

-

 


URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201500733/1/