Pole position identification for synchronous motors at standstill (8400 StateLine and HighLine from V11.0, TopLine from V02.0)

Which products are affected?
StateLine with firmware version V11.00
HighLine with firmware version V11.00
TopLine with firmware version V02.00

Functional description
During synchronous motor operation (encoderless or with incremental encoder systems or in applications including resolvers from third-party motors), the pole position can be identified e.g. every time the controller is enabled.
The identification takes less than 15 ms and reaches an accuracy of 5-10° electrical which helps achieve good control characteristics of the synchronous motors.
The 8400TopLine is provided with the 'Pole position identification 360°' function for further optimisation.

Applications
Applications where the synchronous motor is operated without feedback system.
Applications where the synchronous motor is operated with an incremental feedback system.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201205333/1/