Wrong LED display of the basic device state at the module

Which products are affected?
EMF 2113 Interbus communication module FV ≤ 1.1

What happens?
The two basic device LEDs at the communication module do not correctly display the current status of the two LEDs at the basic device. The function restriction and its elimination is described in detail in in the following article: Correction of the basic device status LED display at the module (elimination) (Doc-ID 200708489).

When does the problem occur?
The problem occurs if the 8200 vector, 9300 and ECS compact servo is used.

Possible diagnostics?
The faulty behaviour described before has occurred if the status of the two basic device LEDs at the module does not match with the current status of the basic device.

Short-term measures/recommendations?
None.

Evaluation:
A controlled drive status can always be ensured since the basic device status is transmitted correctly via the AIF status word to the module and thus also to the higher-level PLC.

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/200708488/1/