Display code C0056

Which products are affected?

8200vector 0.25 - 90 kW (≥ SW 3.5)
8200motec 0.25 - 7.5 kW (≥ SW 3.5)

Function description

With vector control (C0014 = 4 or 5), display code C0056 can indicate the actual torque value MCTRL1-MACT. For this, bit 0 of code C0311 has to be set to 0. If the frequency inverter is operated with U/f characteristic control, code C0056 indicates the active current MCTRL1-MOUT.
If bit 0 of code C0311 is set to 1 (default setting), code C0056 still indicates the active current of the inverter MCTRL1-MOUT for the operation with U/f characteristic control and vector control.

Applications

Operation of the frequency inverter with vector control, display/visualisation of the actual torque value. The display corresponds to the analog value MCTRL1-MACT, which can be connected e. g. to the analog output AOUT. For the previous software versions (< SW 3.5), this was not possible.