Stopping the parameter downlaod when using the process parameter calibration

Which products are affected?

8200motec and 8200vector in connection with the PC software Global Drive Control (GDC)

How is the reaction?

During parameter download there is the error indication that codes C2011, C4011 and C6011 cannot be described.

When does the problem occur?

This error indication can occur, when a device parameter setting is written from the GDC with configurable calibration of the process parameters.

Possible diagnostics?

During parameter download there is the error indication that codes C2011, C4011 and C6011 cannot be described.

Short-term measures / recommendations?

Make the parameter download without configured data in C0500 and C0501 (default setting data). After download to the drive controller modify the value in C0500 and C0501.

Evaluation:

The parameter download is interrupted by an error indication. The functional parameter setting (signal engagement etc.) is effected correctly.