TP positioning and Prg-Stop

Which products are affected?

9300EP servo positioning controller version V2.1

What happens?

If Touch Probe positioning has been interrupted by Prg-Stop, the TP was no longer initialised properly after continuation of TP positioning (Prg-Stop = Low) so it was not evaluated either.

When does the problem occur?

After continuation of a TP positioning (Prg-Stop = Low) if there has been a Prg-Stop before.

Possible diagnostics?

Interrupt TP positioning before the occurrence of TP by Prg-Stop. Then check whether there is a response to the TP.

Short-term measures/recommendations?

After Prg-Stop also perform a program reset in order to restart TP positioning again.

Evaluation:

The phenomenon only occurs if stopping is performed by Prg-Stop anyway so a program reset will be acceptable here.