9400 with SM100 - Safe stop 1 with BBH SMX 11 - performance level e
Function: When the safety function is requested, the motor is stopped according to stop category 1 of EN 60204-1. The delay time in the SMX 11 must be longer than the QSP time. The values to be set depend on the application.
Since the SM100 does not contribute to the probability of failure on demand (PFD) and to the probability of failure per hour (PFH), the feedback DO1 need not be used. All safety-relevant errors that can occur in the SM100 result in the safe state. Faults have been excluded for protected cables (according to DIN EN ISO 13849-2:2008-09 and IEC 61800-5-2:2008-04). This applies to cables which are protected by a cable duct and installed inside the control cabinet.
If the deceleration ramp shall be monitored, the safety characteristics will change as follows: Since the encoder is used to monitor the ramp now, it needs to be considered in the evaluation of the safety characteristics.
Safety information / disclaimer:
The safety application and parameterisation notes are examples of possible subfunctions in machines.
The T10D value according to DIN EN ISO 13849-1, Annex C.4.2 is only indicated if a B10D value is available and the operating time is less than 20 years. Commissioning is prohibited until the machine has been checked in accordance with the regulations set out in the relevant EU directives / national laws. The safety instructions contained in the technical documentation must be observed. Using the examples does not exempt the user from careful project planning. For possible damages and consequential damages Lenze assumes no liability to the extent permitted by law. Copyright 2019 Lenze Automation GmbH