L_TT1P: Drive errors cannot be acknowledged (corrected from V3.15.0)

Corrected from:
L_TT1P_TechnologyModules_LM (V3.15.0.32)
 
Response of the new version:  
Drive errors that are no longer pending (dwDriveError) can be acknowledged with xReset.
 
 
What happens?
Drive errors that are no longer pending (dwDriveError) cannot be acknowledged with xReset.
 
When does this behaviour occur?
  • An i700 axis reports an error (e.g. motor temperature too high)
  • After that, the technology module is activated (xEnabled = TRUE) and the controller is enabled (xRegulatorOn = TRUE) 
  • The technology module indicates an error (xError = TRUE)
  • An error reset is performed (Important step; xReset = TRUE) --> Since the error is still pending, the error message does not disappear
  • Now, the error is reset in the controller (e.g. motor temperature is no longer too high)
  • Another error reset is performed (xReset = TRUE) --> After this, the error message can no longer be acknowledged.
 
Which products are affected?
All technology modules from the L_TT1P_TechnologyModules_LM library (all versions)
 
Short-term measures:
None 
 

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201700130/1/
Modulo di contatto