L_TT1P_VirtualMasterHigh: Axis moves despite "AxisNotHomed" error message (corrected from V3.17.0)

Corrected from:
Library:  L_TT1P_TechnologyModules_LM from V03.17.0.47
                    (update via Easy Package Manager)
 
Response of the new version:
The VirtualMasterHigh technology module is operated with a real axis at the VirtualAxis input. The axis is not homed.
xContinuous is set to TRUE --> the axis does not move
The xError = TRUE and eErrorID = "AxisNotHomed" error messages occur at the VirtalMasterHigh technology module.
 
What happens?
The axis connected to the technology module can be moved although an error message (AxisNotHomed) is pending.
 
When does this behaviour occur?
The VirtualMasterHigh technology module is operated with a real axis at the VirtualAxis input. The axis is not homed.
The xError = TRUE and eErrorID = "AxisNotHomed" error messages occur at the VirtalMasterHigh technology module.
xContinuous is set to TRUE --> the axis starts moving
 
Which products are affected?
L_TT1P_VirtualMasterHigh function block in the L_TT1P_TechnologyModules_LM library (V3.16.0.62 and higher)
 
Short-term measures:
None

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201800095/1/