L_TT1P_RegisterControl: When exceeding a certain speed, TP mark control no longer works (corrected from V3.12)

​Corrected from:
L_TT1P_TechnologyModules_LM library V3.12.0.9

Response of the new version: 
Mark correction will no longer be deactivated due to the size of the correction window. When selecting a correction window > the mark distance, the window will be limited to the mark distance.
                                                                                                                                                                

What happens?
The RegisterControl TM no longer compensates mark errors.

When does this behaviour occur?
The correction window has the same size as the register length. 
 
Which products are affected?
L_TT1P_RegisterControl function block from the L_TT1P_TechnologyModules_LM library (V3.10.0.8 and higher)
 
Short-term measures:
Select the size of the correction window <= the register length.
Recommendation: max. 90%
 
Evaluation/recommendations:

URL for linking this AKB article: https://www.lenze.com/en-de/go/akb/201500618/1/