Behaviour of the new version:
The order of the two frames of the L_Main visualisation was changed to ensure that the right frame for selecting the module visualisations will be selected when clicking L_Main.
What happens?
The L_Main visualisation has got two frames. To change in L_Main between the visualisations of the planned modules, you have to select the module visualisations in the frame selection of the 'GenElemInst_8' frame. Every time this frame is clicked, the 'fraTopMaster' frame is selected.
When does the problem occur?
The 'GenElemInst_8' frame is superimposed by the 'fraTopMaster' frame and completely covered by it.
Which products are affected?
PLC Designer V3.3 and higher
Application Template V3.3 and higher
Diagnostics options:
None
Short-term measures/recommendations:
Open the element list (menu Visualisation>Element List) of the L_Main visualisation and select the 'GenElemInst_8' frame. Then open the frame selection dialog (menu Visualisation>Frame Selection) and select the module visualisations.
Evaluation:
It is not posible to open the right frame to insert the module visualisations into the main visualisation by clicking the L_Main visualisation.
Taxonomy:
AT StartUp Project Standard
,
AT StartUp Project PackML
,
Lib L_EATP_ApplicationTemplate
,
Application Templates
AKB-ID:
201304163
Last update:
2023/09/09
Category:
Version Informations